- Judging conditions:
- If one of the following conditions occurred the lamp life is over.
- The luminance of lamp central section becomes less then 50% of initial value.
- Starting voltage is higher than the rated voltage.
|
|
|
|
|
|
- Testing items:
- Rated life: Rated life is the testing time when the rest good lamps equal to 50% of total
testing conditions:
Testing conditions:
Ambient temperature: normal(25°C)
Current : 5rnA
Power on frequency: continuous
- Low temperature life:
Testing conditions: Low temperature life
Ambient temperature:0°C±1°C
Current :5mA
Power on frequency: continuous
- On-off life:
Testing conditions:
Current :5mA
Cycle time :l0sec. on and 10sec.off
|
|
Rated Life
25,000Hrs
|
Rated Life
500Hrs
|
Rated Life
200,000
|
|
|
- Application Environments:
|
|
|
|
Items
|
Specifications
|
Remarks
|
|
Operation temperature
|
0°C~60°C
|
No condensation
|
|
Storage temperature
|
-30°C~70°C
|
|
Relative humidity
|
90%
|
|
|
|
|
|
|
|
|
|
©2003 Clio Technologies, Inc. All Rights Reserved 1810 Eber Rd Suite C2
Holland, Ohio 43528 419-868-7290 Fax 419-868-7291
|