No.
|
Items
|
Conditions
|
Specifications
|
|
1
|
Impact testing
|
6.3.1
|
C,E
|
|
2
|
vibration testing
|
6.3.2
|
C,E
|
|
3
|
Terminal tensil strength testing
|
6.3.3
|
C,E
|
|
4
|
Heat-cycle testing
|
6.3.4
|
A,C,D,E
|
|
5
|
High temperature & humidity testing
|
6.3.5
|
A,B,C,D,F
|
|
6
|
High temperature testing
|
6.3.6
|
A,C,D,F
|
|
7
|
Low temperature testing
|
6.3.7
|
A,B,C,D,F
|
|
8
|
High temperature & humidity operation testing
|
6.3.8
|
A,B,C,D,F
|
|
9
|
Seal up testing
|
6.3.9
|
C,D,E
|
|
10
|
Snaking testing
|
6.3.10
|
G
|
|
11
|
Low temperature operation testing
|
6.3.11
|
A,B,C,D,F
|
- Notes:
- According to paragraph 6.3 to do each testing
- The details of specifications are listed in paragraph 6.2
- No lighting during each testing except No. 3,8,11
|
|
|
|
- After reliability testing, the characteristics of testing lamps must be met the following requirements:
- Startup voltage: No over 10% of initial value.
- Luminance: At least 50% of initial value.
- No mechanical or physical damage (e.g. nickel guide pin broken)
- No visible distortion, colorchanging etc.
- No lamp can't light up.
- The luminance should be up to 95% of it stability, after power on 3 minutes.
- No darken, color changing in appearance, or unnormal lighting (flicking smacking etc)
|
|