Reliability Testing
Testing Conditions:
    • Impact testing:
    Pulse wave of 30G, llm/sec2 should be applied three times each in X,Y,Z directions.The lamp should be held on the testing fixture.

    • Vibration test:
    Acceleration 19.6m/sec2,frequency 20-500-20Hz be applied in 3 minutes each time, and each In X,Y,Z directions for lhr. Be careful to prevent resonant point.

    • Terminal wire intensity test:
    Tube axial load: lkg
    Time:5 sec.

    • Heat-cycle test:
      Operating 10 cycles as following condition
    • High-temperature & humidity storage test:
      Temperature:70±2°C
      Humidity: 90±5%R.H
      Time: 500hrs
      The lamps should be preserved at room temperature for 2 hrs before doing function testing.

    • High temperature storage test:
      Temperature: 70±2O°C (Dry)
      Time: 1000hrs
      The lamps should be preserved at room temperature for 2 hrs before doing function testing.

    • Low-temperature storage test:
      Temperature: -30°C ±2O°C
      Time: 1000hrs
      The lamps should be preserved at room temperature for 2 hrs before doing function testing.

    • High-temperature & humidity operating test
    Temperature: 40±°C
    Humidity: 90%R.H
    Time: 5mA
    Current: 5mA

    • Sealed test:
    Sampling 40pcs dipped in the boiling water(>95°C) for 10 sec, then dipped in 4°C water for 10 sec. Doing cycle 3 times. All samples should be passed, if there is one fail, do the Next test again.

    • Snaking test:
      Temperature: 50±2°C
      Time: 24hrs
      Current:5mA
      The lamps should be preserved at >0°C ±2 temperature for 2 hrs before doing function
      testing.

    • Low-temperature operation test:
    Temperature:0±1°C Time: 5mA The lamps should be preserved at room temperature for 2 hrs before doing function testing. testing.